GovSteamFV4 Class

Detailed electro-hydraulic governor for steam unit.

Diagram
Свойства (51)
ID Тип Описание Количество
kf1 PU Frequency bias (reciprocal of droop) (<i>Kf1</i>). Typical value = 20. 1..1
kf3 PU Frequency control (reciprocal of droop) (<i>Kf3</i>). Typical value = 20. 1..1
lps PU Maximum positive power error (<i>Lps</i>). Typical value = 0,03. 1..1
lpi PU Maximum negative power error (<i>Lpi</i>). Typical value = -0,15. 1..1
mxef PU Upper limit for frequency correction (<i>MX</i><i><sub>EF</sub></i>). Typical value = 0,05. 1..1
mnef PU Lower limit for frequency correction (<i>MN</i><i><sub>EF</sub></i>). Typical value = -0,05. 1..1
crmx PU Maximum value of regulator set-point (<i>Crmx</i>). Typical value = 1,2. 1..1
crmn PU Minimum value of regulator set-point (<i>Crmn</i>). Typical value = 0. 1..1
kpt PU Proportional gain of electro-hydraulic regulator (<i>Kpt</i>). Typical value = 0,3. 1..1
kit PU Integral gain of electro-hydraulic regulator (<i>Kit</i>). Typical value = 0,04. 1..1
rvgmx PU Maximum value of integral regulator (<i>Rvgmx</i>). Typical value = 1,2. 1..1
rvgmn PU Minimum value of integral regulator (<i>Rvgmn</i>). Typical value = 0. 1..1
svmx Float Maximum regulator gate opening velocity (<i>Svmx</i>). Typical value = 0,0333. 1..1
svmn Float Maximum regulator gate closing velocity (<i>Svmn</i>). Typical value = -0,0333. 1..1
srmx PU Maximum valve opening (<i>Srmx</i>). Typical value = 1,1. 1..1
srmn PU Minimum valve opening (<i>Srmn</i>). Typical value = 0. 1..1
kpp PU Proportional gain of pressure feedback regulator (<i>Kpp</i>). Typical value = 1. 1..1
kip PU Integral gain of pressure feedback regulator (<i>Kip</i>). Typical value = 0,5. 1..1
rsmimx PU Maximum value of integral regulator (<i>Rsmimx</i>). Typical value = 1,1. 1..1
rsmimn PU Minimum value of integral regulator (<i>Rsmimn</i>). Typical value = 0. 1..1
kmp1 PU First gain coefficient of intercept valves characteristic (<i>Kmp1</i>). Typical value = 0,5. 1..1
kmp2 PU Second gain coefficient of intercept valves characteristic (<i>Kmp2</i>). Typical value = 3,5. 1..1
srsmp PU Intercept valves characteristic discontinuity point (<i>Srsmp</i>). Typical value = 0,43. 1..1
ta Seconds Control valves rate opening time (<i>Ta</i>) (&gt;= 0). Typical value = 0,8. 1..1
tc Seconds Control valves rate closing time (<i>Tc</i>) (&gt;= 0). Typical value = 0,5. 1..1
ty Seconds Control valves servo time constant (<i>Ty</i>) (&gt;= 0). Typical value = 0,1. 1..1
yhpmx PU Maximum control valve position (<i>Yhpmx</i>). Typical value = 1,1. 1..1
yhpmn PU Minimum control valve position (<i>Yhpmn</i>). Typical value = 0. 1..1
tam Seconds Intercept valves rate opening time (<i>Tam</i>) (&gt;= 0). Typical value = 0,8. 1..1
tcm Seconds Intercept valves rate closing time (<i>Tcm</i>) (&gt;= 0). Typical value = 0,5. 1..1
ympmx PU Maximum intercept valve position (<i>Ympmx</i>). Typical value = 1,1. 1..1
ympmn PU Minimum intercept valve position (<i>Ympmn</i>). Typical value = 0. 1..1
y PU Coefficient of linearized equations of turbine (Stodola formulation) (<i>Y</i>). Typical value = 0,13. 1..1
thp Seconds High pressure (HP) time constant of the turbine (<i>Thp</i>) (&gt;= 0). Typical value = 0,15. 1..1
trh Seconds Reheater time constant of the turbine (<i>Trh</i>) (&gt;= 0). Typical value = 10. 1..1
tmp Seconds Low pressure (LP) time constant of the turbine (<i>Tmp</i>) (&gt;= 0). Typical value = 0,4. 1..1
khp PU Fraction of total turbine output generated by HP part (<i>Khp</i>). Typical value = 0,35. 1..1
pr1 PU First value of pressure set point static characteristic (<i>Pr1</i>). Typical value = 0,2. 1..1
pr2 PU Second value of pressure set point static characteristic, corresponding to <i>Ps0</i> = 1,0 PU (<i>Pr2</i>). Typical value = 0,75. 1..1
psmn PU Minimum value of pressure set point static characteristic (<i>Psmn</i>). Typical value = 1. 1..1
kpc PU Proportional gain of pressure regulator (<i>Kpc</i>). Typical value = 0,5. 1..1
kic PU Integral gain of pressure regulator (<i>Kic</i>). Typical value = 0,0033. 1..1
kdc PU Derivative gain of pressure regulator (<i>Kdc</i>). Typical value = 1. 1..1
tdc Seconds Derivative time constant of pressure regulator (<i>Tdc</i>) (&gt;= 0). Typical value = 90. 1..1
cpsmx PU Maximum value of pressure regulator output (<i>Cpsmx</i>). Typical value = 1. 1..1
cpsmn PU Minimum value of pressure regulator output (<i>Cpsmn</i>). Typical value = -1. 1..1
krc PU Maximum variation of fuel flow (<i>Krc</i>). Typical value = 0,05. 1..1
tf1 Seconds Time constant of fuel regulation (<i>Tf1</i>) (&gt;= 0). Typical value = 10. 1..1
tf2 Seconds Time constant of steam chest (<i>Tf2</i>) (&gt;= 0). Typical value = 10. 1..1
tv Seconds Boiler time constant (<i>Tv</i>) (&gt;= 0). Typical value = 60. 1..1
ksh PU Pressure loss due to flow friction in the boiler tubes (<i>Ksh</i>). Typical value = 0,08. 1..1
Информация о классе
ID
cim:GovSteamFV4
Тип
Class
Наследует
cim:TurbineGovernorDynamics
Свойств
51