GovSteamFV3 Class

Simplified GovSteamIEEE1 steam turbine governor with Prmax limit and fast valving.

Diagram
Свойства (31)
ID Тип Описание Количество
mwbase ActivePower Base for power values (<i>MWbase</i>) (&gt; 0). Unit = MW. 1..1
k PU Governor gain, (reciprocal of droop) (<i>K</i>). Typical value = 20. 1..1
t1 Seconds Governor lead time constant (<i>T1</i>) (&gt;= 0). Typical value = 0. 1..1
t2 Seconds Governor lag time constant (<i>T2</i>) (&gt;= 0). Typical value = 0. 1..1
t3 Seconds Valve positioner time constant (<i>T3</i>) (&gt; 0). Typical value = 0. 1..1
uo Float Maximum valve opening velocity (<i>Uo</i>). Unit = PU / s. Typical value = 0,1. 1..1
uc Float Maximum valve closing velocity (<i>Uc</i>). Unit = PU / s. Typical value = -1. 1..1
pmax PU Maximum valve opening, PU of <i>MWbase</i> (<i>Pmax</i>) (&gt; GovSteamFV3.pmin). Typical value = 1. 1..1
pmin PU Minimum valve opening, PU of <i>MWbase</i> (<i>Pmin</i>) (&lt; GovSteamFV3.pmax). Typical value = 0. 1..1
t4 Seconds Inlet piping/steam bowl time constant (<i>T4</i>) (&gt;= 0). Typical value = 0,2. 1..1
k1 PU Fraction of turbine power developed after first boiler pass (<i>K1</i>). Typical value = 0,2. 1..1
t5 Seconds Time constant of second boiler pass (i.e. reheater) (<i>T5</i>) (&gt; 0 if fast valving is used, otherwise &gt;= 0). Typical value = 0,5. 1..1
k2 PU Fraction of turbine power developed after second boiler pass (<i>K2</i>). Typical value = 0,2. 1..1
t6 Seconds Time constant of crossover or third boiler pass (<i>T6</i>) (&gt;= 0). Typical value = 10. 1..1
k3 PU Fraction of hp turbine power developed after crossover or third boiler pass (<i>K3</i>). Typical value = 0,6. 1..1
ta Seconds Time to close intercept valve (IV) (<i>Ta</i>) (&gt;= 0). Typical value = 0,97. 1..1
tb Seconds Time until IV starts to reopen (<i>Tb</i>) (&gt;= 0). Typical value = 0,98. 1..1
tc Seconds Time until IV is fully open (<i>Tc</i>) (&gt;= 0). Typical value = 0,99. 1..1
prmax PU Max. pressure in reheater (<i>Prmax</i>). Typical value = 1. 1..1
gv1 PU Nonlinear gain valve position point 1 (<i>GV1</i>). Typical value = 0. 1..1
pgv1 PU Nonlinear gain power value point 1 (<i>Pgv1</i>). Typical value = 0. 1..1
gv2 PU Nonlinear gain valve position point 2 (<i>GV2</i>). Typical value = 0,4. 1..1
pgv2 PU Nonlinear gain power value point 2 (<i>Pgv2</i>). Typical value = 0,75. 1..1
gv3 PU Nonlinear gain valve position point 3 (<i>GV3</i>). Typical value = 0,5. 1..1
pgv3 PU Nonlinear gain power value point 3 (<i>Pgv3</i>). Typical value = 0,91. 1..1
gv4 PU Nonlinear gain valve position point 4 (<i>GV4</i>). Typical value = 0,6. 1..1
pgv4 PU Nonlinear gain power value point 4 (<i>Pgv4</i>). Typical value = 0,98. 1..1
gv5 PU Nonlinear gain valve position point 5 (<i>GV5</i>). Typical value = 1. 1..1
pgv5 PU Nonlinear gain power value point 5 (<i>Pgv5</i>). Typical value = 1. 1..1
gv6 PU Nonlinear gain valve position point 6 (<i>GV6</i>). Typical value = 0. 1..1
pgv6 PU Nonlinear gain power value point 6 (<i>Pgv6</i>). Typical value = 0. 1..1
Информация о классе
ID
cim:GovSteamFV3
Тип
Class
Наследует
cim:TurbineGovernorDynamics
Свойств
31