ActivePower Data Type
Product of RMS value of the voltage and the RMS value of the in-phase component of the current.
Ссылки (73)
| Класс | Свойство | Описание |
|---|---|---|
| cim:AsynchronousMachine | cim:ratedMechanicalPower |
Rated mechanical power (Pr in IEC 60909-0). Used for short circuit data exchange according to IEC 60909. |
| cim:RotatingMachine | cim:p |
Active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution. |
| cim:EnergySource | cim:pMin |
This is the minimum active power that can be produced by the source. Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment. |
| cim:EnergySource | cim:pMax |
This is the maximum active power that can be produced by the source. Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment. |
| cim:EnergySource | cim:activePower |
High voltage source active injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions. |
| cim:EquivalentInjection | cim:maxP |
Maximum active power of the injection. |
| cim:EquivalentInjection | cim:minP |
Minimum active power of the injection. |
| cim:EquivalentInjection | cim:p |
Equivalent active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions. |
| cim:ExternalNetworkInjection | cim:maxP |
Maximum active power of the injection. |
| cim:ExternalNetworkInjection | cim:minP |
Minimum active power of the injection. |
| cim:ExternalNetworkInjection | cim:p |
Active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for steady state solutions. |
| cim:ACDCConverter | cim:poleLossP |
The active power loss at a DC Pole = idleLoss + switchingLoss*|Idc| + resitiveLoss*Idc^2. For lossless operation Pdc=Pac. For rectifier operation with losses Pdc=Pac-lossP. For inverter operation with losses Pdc=Pac+lossP. It is converter’s state variable used in power flow. The attribute shall be a positive value. |
| cim:ACDCConverter | cim:idleLoss |
Active power loss in pole at no power transfer. It is converter’s configuration data used in power flow. The attribute shall be a positive value. |
| cim:ACDCConverter | cim:maxP |
Maximum active power limit. The value is overwritten by values of VsCapabilityCurve, if present. |
| cim:ACDCConverter | cim:minP |
Minimum active power limit. The value is overwritten by values of VsCapabilityCurve, if present. |
| cim:ACDCConverter | cim:p |
Active power at the point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution in the case a simplified power flow model is used. |
| cim:ACDCConverter | cim:targetPpcc |
Real power injection target in AC grid, at point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node. |
| cim:SvInjection | cim:pInjection |
The active power mismatch between calculated injection and initial injection. Positive sign means injection into the TopologicalNode (bus). |
| cim:SvPowerFlow | cim:p |
The active power flow. Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment. |
| cim:EnergyConsumer | cim:pfixed |
Active power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is used, i.e. positive sign means flow out from a node. |
| cim:EnergyConsumer | cim:p |
Active power of the load. Load sign convention is used, i.e. positive sign means flow out from a node. For voltage dependent loads the value is at rated voltage. Starting value for a steady state solution. |
| cim:PowerElectronicsConnection | cim:p |
Active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution. |
| cim:GovHydroIEEE0 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovHydroIEEE2 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovSteamIEEE1 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0)<i>. </i>Unit = MW. |
| cim:GovCT1 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovCT2 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovGAST | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovGAST1 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovGAST1 | cim:db2 |
Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value = 0. |
| cim:GovGAST2 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovGAST2 | cim:trate |
Turbine rating (<i>Trate</i>). Unit = MW. |
| cim:GovGASTWD | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovGASTWD | cim:trate |
Turbine rating (<i>Trate</i>). Unit = MW. |
| cim:GovHydro1 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovHydro2 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovHydro2 | cim:db2 |
Unintentional deadband (<i>db2</i>). Unit = MW. Typical value = 0. |
| cim:GovHydro3 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovHydro3 | cim:db2 |
Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value = 0. |
| cim:GovHydro4 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovHydro4 | cim:db2 |
Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value = 0. |
| cim:GovHydroDD | cim:mwbase |
Base for power values (<i>MWbase</i>) (>0). Unit = MW. |
| cim:GovHydroDD | cim:db2 |
Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value = 0. |
| cim:GovHydroPID | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovHydroPID | cim:db2 |
Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value = 0. |
| cim:GovHydroPID2 | cim:mwbase |
Base for power values (<i>MWbase</i>) (>0). Unit = MW. |
| cim:GovHydroR | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovHydroR | cim:db2 |
Unintentional dead-band (<i>db2</i>). Unit = MW. Typical value = 0. |
| cim:GovHydroWEH | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovHydroWPID | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovSteam0 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovSteam1 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovSteam1 | cim:db2 |
Unintentional deadband (<i>db2</i>). Unit = MW. Typical value = 0. |
| cim:GovSteamCC | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovSteamEU | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovSteamFV2 | cim:mwbase |
Alternate base used instead of machine base in equipment model if necessary (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovSteamFV3 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:GovSteamSGO | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:TurbLCFB1 | cim:mwbase |
Base for power values (<i>MWbase</i>) (> 0). Unit = MW. |
| cim:TurbLCFB1 | cim:pmwset |
Power controller setpoint (<i>Pmwset</i>) (see parameter detail 1). Unit = MW. Typical value = 0. |
| cim:ActivePowerLimit | cim:normalValue |
The normal value of active power limit. The attribute shall be a positive value or zero. |
| cim:ActivePowerLimit | cim:value |
Value of active power limit. The attribute shall be a positive value or zero. |
| cim:PowerElectronicsUnit | cim:maxP |
Maximum active power limit. This is the maximum (nameplate) limit for the unit. |
| cim:PowerElectronicsUnit | cim:minP |
Minimum active power limit. This is the minimum (nameplate) limit for the unit. |
| cim:ControlArea | cim:netInterchange |
The specified positive net interchange into the control area, i.e. positive sign means flow into the area. |
| cim:ControlArea | cim:pTolerance |
Active power net interchange tolerance. The attribute shall be a positive value or zero. |
| cim:GeneratingUnit | cim:maximumAllowableSpinningReserve |
Maximum allowable spinning reserve. Spinning reserve will never be considered greater than this value regardless of the current operating point. |
| cim:GeneratingUnit | cim:maxOperatingP |
This is the maximum operating active power limit the dispatcher can enter for this unit. |
| cim:GeneratingUnit | cim:minOperatingP |
This is the minimum operating active power limit the dispatcher can enter for this unit. |
| cim:GeneratingUnit | cim:nominalP |
The nominal power of the generating unit. Used to give precise meaning to percentage based attributes such as the governor speed change droop (governorSCD attribute). The attribute shall be a positive value equal to or less than RotatingMachine.ratedS. |
| cim:GeneratingUnit | cim:ratedGrossMaxP |
The unit's gross rated maximum capacity (book value). The attribute shall be a positive value. |
| cim:GeneratingUnit | cim:ratedGrossMinP |
The gross rated minimum generation level which the unit can safely operate at while delivering power to the transmission grid. The attribute shall be a positive value. |
| cim:GeneratingUnit | cim:ratedNetMaxP |
The net rated maximum capacity determined by subtracting the auxiliary power used to operate the internal plant machinery from the rated gross maximum capacity. The attribute shall be a positive value. |
Информация о классе
- ID
ActivePower- Тип
- Data Type