GovSteamIEEE1 Class

IEEE steam turbine governor model. Ref<font color="#0f0f0f">erence: IEEE Transactions on Power Apparatus and Systems, November/December 1973, Volume PAS-92, Number 6, <i><u>Dynamic Models for Steam and Hydro Turbines in Power System Studies</u></i>, page 1904.</font>

Diagram
Свойства (21)
ID Тип Описание Количество
mwbase ActivePower Base for power values (<i>MWbase</i>) (&gt; 0)<i>. </i>Unit = MW. 1..1
k PU Governor gain (reciprocal of droop) (<i>K</i>) (&gt; 0). Typical value = 25. 1..1
t1 Seconds Governor lag time constant (<i>T1</i>) (&gt;= 0). Typical value = 0. 1..1
t2 Seconds Governor lead time constant (<i>T2</i>) (&gt;= 0). Typical value = 0. 1..1
t3 Seconds Valve positioner time constant (<i>T3</i>) (&gt; 0). Typical value = 0,1. 1..1
uo Float Maximum valve opening velocity (<i>Uo</i>) (&gt; 0). Unit = PU / s. Typical value = 1. 1..1
uc Float Maximum valve closing velocity (<i>Uc</i>) (&lt; 0). Unit = PU / s. Typical value = -10. 1..1
pmax PU Maximum valve opening (<i>Pmax</i>) (&gt; GovSteamIEEE1.pmin). Typical value = 1. 1..1
pmin PU Minimum valve opening (<i>Pmin</i>) (&gt;= 0 and &lt; GovSteamIEEE1.pmax). Typical value = 0. 1..1
t4 Seconds Inlet piping/steam bowl time constant (<i>T4</i>) (&gt;= 0). Typical value = 0,3. 1..1
k1 Float Fraction of HP shaft power after first boiler pass (<i>K1</i>). Typical value = 0,2. 1..1
k2 Float Fraction of LP shaft power after first boiler pass (<i>K2</i>). Typical value = 0. 1..1
t5 Seconds Time constant of second boiler pass (<i>T5</i>) (&gt;= 0). Typical value = 5. 1..1
k3 Float Fraction of HP shaft power after second boiler pass (<i>K3</i>). Typical value = 0,3. 1..1
k4 Float Fraction of LP shaft power after second boiler pass (<i>K4</i>). Typical value = 0. 1..1
t6 Seconds Time constant of third boiler pass (<i>T6</i>) (&gt;= 0). Typical value = 0,5. 1..1
k5 Float Fraction of HP shaft power after third boiler pass (<i>K5</i>). Typical value = 0,5. 1..1
k6 Float Fraction of LP shaft power after third boiler pass (<i>K6</i>). Typical value = 0. 1..1
t7 Seconds Time constant of fourth boiler pass (<i>T7</i>) (&gt;= 0). Typical value = 0. 1..1
k7 Float Fraction of HP shaft power after fourth boiler pass (<i>K7</i>). Typical value = 0. 1..1
k8 Float Fraction of LP shaft power after fourth boiler pass (<i>K8</i>). Typical value = 0. 1..1