GovSteamSGO Class

Simplified steam turbine governor.

Diagram
Свойства (12)
ID Тип Описание Количество
mwbase ActivePower Base for power values (<i>MWbase</i>) (&gt; 0). Unit = MW. 1..1
t1 Seconds Controller lag (<i>T1</i>) (&gt;= 0). 1..1
t2 Seconds Controller lead compensation (<i>T2</i>) (&gt;= 0). 1..1
t3 Seconds Governor lag (<i>T3</i>) (&gt; 0). 1..1
t4 Seconds Delay due to steam inlet volumes associated with steam chest and inlet piping (<i>T4</i>) (&gt;= 0). 1..1
t5 Seconds Reheater delay including hot and cold leads (<i>T5</i>) (&gt;= 0). 1..1
t6 Seconds Delay due to IP-LP turbine, crossover pipes and LP end hoods (<i>T6</i>) (&gt;= 0). 1..1
k1 PU One / PU regulation (<i>K1</i>). 1..1
k2 PU Fraction (<i>K2</i>). 1..1
k3 PU Fraction (<i>K3</i>). 1..1
pmax PU Upper power limit (<i>Pmax</i>) (&gt; GovSteamSGO.pmin). 1..1
pmin Seconds Lower power limit (<i>Pmin</i>) (&gt;= 0 and &lt; GovSteamSGO.pmax). 1..1
Информация о классе
ID
cim:GovSteamSGO
Тип
Class
Наследует
cim:TurbineGovernorDynamics
Свойств
12