Frequency Data Type

Cycles per second.

Ссылки (30)
Класс Свойство Описание
cim:AsynchronousMachine cim:nominalFrequency

Nameplate data indicates if the machine is 50 Hz or 60 Hz.

cim:GovCT2 cim:flim1

Frequency threshold 1 (<i>Flim1</i>). Unit = Hz. Typical value = 59.

cim:GovCT2 cim:flim2

Frequency threshold 2 (<i>Flim2</i>). Unit = Hz. Typical value = 0.

cim:GovCT2 cim:flim3

Frequency threshold 3 (<i>Flim3</i>). Unit = Hz. Typical value = 0.

cim:GovCT2 cim:flim4

Frequency threshold 4 (<i>Flim4</i>). Unit = Hz. Typical value = 0.

cim:GovCT2 cim:flim5

Frequency threshold 5 (<i>Flim5</i>). Unit = Hz. Typical value = 0.

cim:GovCT2 cim:flim6

Frequency threshold 6 (<i>Flim6</i>). Unit = Hz. Typical value = 0.

cim:GovCT2 cim:flim7

Frequency threshold 7 (<i>Flim7</i>). Unit = Hz. Typical value = 0.

cim:GovCT2 cim:flim8

Frequency threshold 8 (<i>Flim8</i>). Unit = Hz. Typical value = 0.

cim:GovCT2 cim:flim9

Frequency threshold 9 (<i>Flim9</i>). Unit = Hz. Typical value = 0.

cim:GovCT2 cim:flim10

Frequency threshold 10 (<i>Flim10</i>). Unit = Hz. Typical value = 0.

cim:GovGAST1 cim:db1

Intentional dead-band width (<i>db1</i>). Unit = Hz. Typical value = 0.

cim:GovGAST1 cim:eps

Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value = 0.

cim:GovHydro2 cim:db1

Intentional deadband width (<i>db1</i>). Unit = Hz. Typical value = 0.

cim:GovHydro2 cim:eps

Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value = 0.

cim:GovHydro3 cim:db1

Intentional dead-band width (<i>db1</i>). Unit = Hz. Typical value = 0.

cim:GovHydro3 cim:eps

Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value = 0.

cim:GovHydro4 cim:db1

Intentional deadband width (<i>db1</i>). Unit = Hz. Typical value = 0.

cim:GovHydro4 cim:eps

Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value = 0.

cim:GovHydroDD cim:db1

Intentional dead-band width (<i>db1</i>). Unit = Hz. Typical value = 0.

cim:GovHydroDD cim:eps

Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value = 0.

cim:GovHydroFrancis cim:db1

Intentional dead-band width (<i>DB1</i>). Unit = Hz. Typical value = 0.

cim:GovHydroPelton cim:db1

Intentional dead-band width (<i>DB1</i>). Unit = Hz. Typical value = 0.

cim:GovHydroPelton cim:db2

Intentional dead-band width of valve opening error (<i>DB2</i>). Unit = Hz. Typical value = 0,01.

cim:GovHydroPID cim:db1

Intentional dead-band width (<i>db1</i>). Unit = Hz. Typical value = 0.

cim:GovHydroPID cim:eps

Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value = 0.

cim:GovHydroR cim:db1

Intentional dead-band width (<i>db1</i>). Unit = Hz. Typical value = 0.

cim:GovHydroR cim:eps

Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value = 0.

cim:GovSteam1 cim:db1

Intentional deadband width (<i>db1</i>). Unit = Hz. Typical value = 0.

cim:GovSteam1 cim:eps

Intentional db hysteresis (<i>eps</i>). Unit = Hz. Typical value = 0.

Информация о классе
ID
Frequency
Тип
Data Type