Resistance Data Type
Resistance (real part of impedance).
Ссылки (33)
| Класс | Свойство | Описание |
|---|---|---|
| cim:ACLineSegment | cim:r0 |
Zero sequence series resistance of the entire line section. |
| cim:ACLineSegment | cim:r |
Positive sequence series resistance of the entire line section. |
| cim:EarthFaultCompensator | cim:r |
Nominal resistance of device. |
| cim:EnergySource | cim:r |
Positive sequence Thevenin resistance. |
| cim:EnergySource | cim:r0 |
Zero sequence Thevenin resistance. |
| cim:EnergySource | cim:rn |
Negative sequence Thevenin resistance. |
| cim:EquivalentBranch | cim:negativeR12 |
Negative sequence series resistance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange. |
| cim:EquivalentBranch | cim:negativeR21 |
Negative sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange. |
| cim:EquivalentBranch | cim:positiveR12 |
Positive sequence series resistance from terminal sequence 1 to terminal sequence 2 . Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange. |
| cim:EquivalentBranch | cim:positiveR21 |
Positive sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange. |
| cim:EquivalentBranch | cim:zeroR12 |
Zero sequence series resistance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange. |
| cim:EquivalentBranch | cim:zeroR21 |
Zero sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange. |
| cim:EquivalentBranch | cim:r |
Positive sequence series resistance of the reduced branch. |
| cim:EquivalentBranch | cim:r21 |
Resistance from terminal sequence 2 to terminal sequence 1 .Used for steady state power flow. This attribute is optional and represent unbalanced network such as off-nominal phase shifter. If only EquivalentBranch.r is given, then EquivalentBranch.r21 is assumed equal to EquivalentBranch.r. Usage rule : EquivalentBranch is a result of network reduction prior to the data exchange. |
| cim:EquivalentInjection | cim:r |
Positive sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange. |
| cim:EquivalentInjection | cim:r0 |
Zero sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange. |
| cim:EquivalentInjection | cim:r2 |
Negative sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange. |
| cim:MutualCoupling | cim:r0 |
Zero sequence branch-to-branch mutual impedance coupling, resistance. |
| cim:PowerTransformerEnd | cim:r0 |
Zero sequence series resistance (star-model) of the transformer end. |
| cim:PowerTransformerEnd | cim:r |
Resistance (star-model) of the transformer end. The attribute shall be equal to or greater than zero for non-equivalent transformers. |
| cim:TransformerEnd | cim:rground |
(for Yn and Zn connections) Resistance part of neutral impedance where 'grounded' is true. |
| cim:SeriesCompensator | cim:r0 |
Zero sequence resistance. |
| cim:SeriesCompensator | cim:r |
Positive sequence resistance. |
| cim:SynchronousMachine | cim:earthingStarPointR |
Generator star point earthing resistance (Re). Used for short circuit data exchange according to IEC 60909. |
| cim:SynchronousMachine | cim:r0 |
Zero sequence resistance of the synchronous machine. |
| cim:SynchronousMachine | cim:r2 |
Negative sequence resistance. |
| cim:SynchronousMachine | cim:r |
Equivalent resistance (RG) of generator. RG is considered for the calculation of all currents, except for the calculation of the peak current ip. Used for short circuit data exchange according to IEC 60909. |
| cim:ACDCConverter | cim:resistiveLoss |
It is converter’s configuration data used in power flow. Refer to poleLossP. The attribute shall be a positive value. |
| cim:VsConverter | cim:droopCompensation |
Compensation constant. Used to compensate for voltage drop when controlling voltage at a distant bus. The attribute shall be a positive value. |
| cim:DCGround | cim:r |
Resistance to ground. |
| cim:DCLineSegment | cim:resistance |
Resistance of the DC line segment. |
| cim:DCSeriesDevice | cim:resistance |
Resistance of the DC device. |
| cim:DCShunt | cim:resistance |
Resistance of the DC device. |
Информация о классе
- ID
Resistance- Тип
- Data Type