Resistance Data Type

Resistance (real part of impedance).

Ссылки (33)
Класс Свойство Описание
cim:ACLineSegment cim:r0

Zero sequence series resistance of the entire line section.

cim:ACLineSegment cim:r

Positive sequence series resistance of the entire line section.

cim:EarthFaultCompensator cim:r

Nominal resistance of device.

cim:EnergySource cim:r

Positive sequence Thevenin resistance.

cim:EnergySource cim:r0

Zero sequence Thevenin resistance.

cim:EnergySource cim:rn

Negative sequence Thevenin resistance.

cim:EquivalentBranch cim:negativeR12

Negative sequence series resistance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.

cim:EquivalentBranch cim:negativeR21

Negative sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.

cim:EquivalentBranch cim:positiveR12

Positive sequence series resistance from terminal sequence 1 to terminal sequence 2 . Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.

cim:EquivalentBranch cim:positiveR21

Positive sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.

cim:EquivalentBranch cim:zeroR12

Zero sequence series resistance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.

cim:EquivalentBranch cim:zeroR21

Zero sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange.

cim:EquivalentBranch cim:r

Positive sequence series resistance of the reduced branch.

cim:EquivalentBranch cim:r21

Resistance from terminal sequence 2 to terminal sequence 1 .Used for steady state power flow. This attribute is optional and represent unbalanced network such as off-nominal phase shifter. If only EquivalentBranch.r is given, then EquivalentBranch.r21 is assumed equal to EquivalentBranch.r. Usage rule : EquivalentBranch is a result of network reduction prior to the data exchange.

cim:EquivalentInjection cim:r

Positive sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange.

cim:EquivalentInjection cim:r0

Zero sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange.

cim:EquivalentInjection cim:r2

Negative sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a result of network reduction prior to the data exchange.

cim:MutualCoupling cim:r0

Zero sequence branch-to-branch mutual impedance coupling, resistance.

cim:PowerTransformerEnd cim:r0

Zero sequence series resistance (star-model) of the transformer end.

cim:PowerTransformerEnd cim:r

Resistance (star-model) of the transformer end. The attribute shall be equal to or greater than zero for non-equivalent transformers.

cim:TransformerEnd cim:rground

(for Yn and Zn connections) Resistance part of neutral impedance where 'grounded' is true.

cim:SeriesCompensator cim:r0

Zero sequence resistance.

cim:SeriesCompensator cim:r

Positive sequence resistance.

cim:SynchronousMachine cim:earthingStarPointR

Generator star point earthing resistance (Re). Used for short circuit data exchange according to IEC 60909.

cim:SynchronousMachine cim:r0

Zero sequence resistance of the synchronous machine.

cim:SynchronousMachine cim:r2

Negative sequence resistance.

cim:SynchronousMachine cim:r

Equivalent resistance (RG) of generator. RG is considered for the calculation of all currents, except for the calculation of the peak current ip. Used for short circuit data exchange according to IEC 60909.

cim:ACDCConverter cim:resistiveLoss

It is converter’s configuration data used in power flow. Refer to poleLossP. The attribute shall be a positive value.

cim:VsConverter cim:droopCompensation

Compensation constant. Used to compensate for voltage drop when controlling voltage at a distant bus. The attribute shall be a positive value.

cim:DCGround cim:r

Resistance to ground.

cim:DCLineSegment cim:resistance

Resistance of the DC line segment.

cim:DCSeriesDevice cim:resistance

Resistance of the DC device.

cim:DCShunt cim:resistance

Resistance of the DC device.