Integer Primitive
An integer number. The range is unspecified and not limited.
Ссылки (36)
| Класс | Свойство | Описание |
|---|---|---|
| cim:DiagramObject | cim:drawingOrder |
The drawing order of this element. The higher the number, the later the element is drawn in sequence. This is used to ensure that elements that overlap are rendered in the correct order. |
| cim:DiagramObjectPoint | cim:sequenceNumber |
The sequence position of the point, used for defining the order of points for diagram objects acting as a polyline or polygon with more than one point. The attribute shall be a positive value. |
| cim:VisibilityLayer | cim:drawingOrder |
The drawing order for this layer. The higher the number, the later the layer and the objects within it are rendered. |
| cim:ACDCTerminal | cim:sequenceNumber |
The orientation of the terminal connections for a multiple terminal conducting equipment. The sequence numbering starts with 1 and additional terminals should follow in increasing order. The first terminal is the "starting point" for a two terminal branch. |
| cim:AsynchronousMachine | cim:polePairNumber |
Number of pole pairs of stator. Used for short circuit data exchange according to IEC 60909. |
| cim:ExternalNetworkInjection | cim:referencePriority |
Priority of unit for use as powerflow voltage phase angle reference bus selection. 0 = don t care (default) 1 = highest priority. 2 is less than 1 and so on. |
| cim:ShuntCompensator | cim:maximumSections |
The maximum number of sections that may be switched in. |
| cim:ShuntCompensator | cim:normalSections |
The normal number of sections switched in. The value shall be between zero and ShuntCompensator.maximumSections. |
| cim:NonlinearShuntCompensatorPoint | cim:sectionNumber |
The number of the section. |
| cim:PowerTransformerEnd | cim:phaseAngleClock |
Terminal voltage phase angle displacement where 360 degrees are represented with clock hours. The valid values are 0 to 11. For example, for the secondary side end of a transformer with vector group code of 'Dyn11', specify the connection kind as wye with neutral and specify the phase angle of the clock as 11. The clock value of the transformer end number specified as 1, is assumed to be zero. Note the transformer end number is not assumed to be the same as the terminal sequence number. |
| cim:TransformerEnd | cim:endNumber |
Number for this transformer end, corresponding to the end's order in the power transformer vector group or phase angle clock number. Highest voltage winding should be 1. Each end within a power transformer should have a unique subsequent end number. Note the transformer end number need not match the terminal sequence number. |
| cim:SynchronousMachine | cim:referencePriority |
Priority of unit for use as powerflow voltage phase angle reference bus selection. 0 = don t care (default) 1 = highest priority. 2 is less than 1 and so on. |
| cim:ACDCConverter | cim:numberOfValves |
Number of valves in the converter. Used in loss calculations. |
| cim:TapChanger | cim:highStep |
Highest possible tap step position, advance from neutral. The attribute shall be greater than lowStep. |
| cim:TapChanger | cim:lowStep |
Lowest possible tap step position, retard from neutral. |
| cim:TapChanger | cim:neutralStep |
The neutral tap step position for this winding. The attribute shall be equal to or greater than lowStep and equal or less than highStep. It is the step position where the voltage is neutralU when the other terminals of the transformer are at the ratedU. If there are other tap changers on the transformer those taps are kept constant at their neutralStep. |
| cim:TapChanger | cim:normalStep |
The tap step position used in "normal" network operation for this winding. For a "Fixed" tap changer indicates the current physical tap setting. The attribute shall be equal to or greater than lowStep and equal to or less than highStep. |
| cim:ProprietaryParameterDynamics | cim:parameterNumber |
Sequence number of the parameter among the set of parameters associated with the related proprietary user-defined model. |
| cim:ProprietaryParameterDynamics | cim:integerParameterValue |
Integer parameter value. If this attribute is populated, booleanParameterValue and floatParameterValue will not be. |
| cim:GovGAST2 | cim:z |
Governor mode (<i>Z</i>). 1 = droop 0 = isochronous. |
| cim:ExcANS | cim:blint |
Governor control flag (<i>BLINT</i>). 0 = lead-lag regulator 1 = proportional integral regulator. Typical value = 0. |
| cim:ExcANS | cim:kvfif |
Rate feedback signal flag (<i>K</i><i><sub>VFIF</sub></i>). 0 = output voltage of the exciter 1 = exciter field current. Typical value = 0. |
| cim:ExcANS | cim:krvecc |
Feedback enabling (<i>K</i><i><sub>RVECC</sub></i>). 0 = open loop control 1 = closed loop control. Typical value = 1. |
| cim:PssIEEE2B | cim:n |
Order of ramp tracking filter (<i>N</i>). Typical value = 1. |
| cim:PssIEEE2B | cim:m |
Denominator order of ramp tracking filter (<i>M</i>). Typical value = 5. |
| cim:Pss2B | cim:n |
Order of ramp tracking filter (<i>n</i>). Typical value = 1. |
| cim:Pss2B | cim:m |
Denominator order of ramp tracking filter (<i>m</i>). Typical value = 5. |
| cim:WindDynamicsLookupTable | cim:sequence |
Sequence numbers of the pairs of the input (<i>x</i>) and the output (<i>y</i>) of the lookup table function. |
| cim:BusNameMarker | cim:priority |
Priority of bus name marker for use as topology bus name. Use 0 for do not care. Use 1 for highest priority. Use 2 as priority is less than 1 and so on. |
| cim:TapChangerTablePoint | cim:step |
The tap step. |
| cim:RegularTimePoint | cim:sequenceNumber |
The position of the regular time point in the sequence. Note that time points don't have to be sequential, i.e. time points may be omitted. The actual time for a RegularTimePoint is computed by multiplying the associated regular interval schedule's time step with the regular time point sequence number and adding the associated schedules start time. To specify values for the start time, use sequence number 0. The sequence number cannot be negative. |
| cim:AccumulatorLimit | cim:value |
The value to supervise against. The value is positive. |
| cim:Command | cim:normalValue |
Normal value for Control.value e.g. used for percentage scaling. |
| cim:Command | cim:value |
The value representing the actuator output. |
| cim:ValueToAlias | cim:value |
The value that is mapped. |
| cim:PositionPoint | cim:sequenceNumber |
Zero-relative sequence number of this point within a series of points. |
Информация о классе
- ID
Integer- Тип
- Primitive