GovGAST2 Class

Gas turbine.

Diagram
Свойства (32)
ID Тип Описание Количество
mwbase ActivePower Base for power values (<i>MWbase</i>) (&gt; 0). Unit = MW. 1..1
w PU Governor gain (1/droop) on turbine rating (<i>W</i>). 1..1
x Seconds Governor lead time constant (<i>X</i>) (&gt;= 0). 1..1
y Seconds Governor lag time constant (<i>Y</i>) (&gt; 0). 1..1
z Integer Governor mode (<i>Z</i>). 1 = droop 0 = isochronous. 1..1
etd Seconds Turbine and exhaust delay (<i>Etd</i>) (&gt;= 0). 1..1
tcd Seconds Compressor discharge time constant (<i>Tcd</i>) (&gt;= 0). 1..1
trate ActivePower Turbine rating (<i>Trate</i>). Unit = MW. 1..1
t Seconds Fuel control time constant (<i>T</i>) (&gt;= 0). 1..1
tmax PU Maximum turbine limit (<i>Tmax</i>) (&gt; GovGAST2.tmin). 1..1
tmin PU Minimum turbine limit (<i>Tmin</i>) (&lt; GovGAST2.tmax). 1..1
ecr Seconds Combustion reaction time delay (<i>Ecr</i>) (&gt;= 0). 1..1
k3 PU Ratio of fuel adjustment (<i>K3</i>). 1..1
a Float Valve positioner (<i>A</i>). 1..1
b Float Valve positioner (<i>B</i>). 1..1
c Float Valve positioner (<i>C</i>). 1..1
tf Seconds Fuel system time constant (<i>Tf</i>) (&gt;= 0). 1..1
kf PU Fuel system feedback (<i>Kf</i>). 1..1
k5 PU Gain of radiation shield (<i>K5</i>). 1..1
k4 PU Gain of radiation shield (<i>K4</i>). 1..1
t3 Seconds Radiation shield time constant (<i>T3</i>) (&gt;= 0). 1..1
t4 Seconds Thermocouple time constant (<i>T4</i>) (&gt;= 0). 1..1
tt Seconds Temperature controller integration rate (<i>Tt</i>) (&gt;= 0). 1..1
t5 Seconds Temperature control time constant (<i>T5</i>) (&gt;= 0). 1..1
af1 PU Exhaust temperature parameter (<i>Af1</i>). Unit = PU temperature. Based on temperature in degrees C. 1..1
bf1 PU (<i>Bf1</i>). <i>Bf1</i> = <i>E</i>(1 - <i>W</i>) where <i>E</i> (speed sensitivity coefficient) is 0,55 to 0,65 x <i>Tr</i>. Unit = PU temperature. Based on temperature in degrees C. 1..1
af2 PU Coefficient equal to 0,5(1-speed) (<i>Af2</i>). 1..1
bf2 PU Turbine torque coefficient K<sub>hhv</sub> (depends on heating value of fuel stream in combustion chamber) (<i>Bf2</i>). 1..1
cf2 PU Coefficient defining fuel flow where power output is 0% (<i>Cf2</i>). Synchronous but no output. Typically 0,23 x K<sub>hhv</sub> (23% fuel flow). 1..1
tr Temperature Rated temperature (<i>Tr</i>). Unit = °C depending on parameters<i> Af1 </i>and <i>Bf1</i>. 1..1
k6 PU Minimum fuel flow (<i>K6</i>). 1..1
tc Temperature Temperature control (<i>Tc</i>). Unit = °F or °C depending on parameters <i>Af1</i> and <i>Bf1</i>. 1..1
Информация о классе
ID
cim:GovGAST2
Тип
Class
Наследует
cim:TurbineGovernorDynamics
Свойств
32